Human IFN-gamma enzyme-linked immunoassay kit
Catalog# EH0039
Human IFN-gamma enzyme-linked immunoassay kit
-
ELISA
-
Human
-
1.37~1000 pg/ml
-
unconjugated
Safety datasheet
Select your chosen country/region
- MSDS_HUABIO.pdf
- MSDS_HUABIO.pdf
- MSDS_EH0039_Europe.pdf
- No MSDS Found
製品概要
製品名
Human IFN-gamma enzyme-linked immunoassay kit
製品タイプ
Elisa Kit
検出感度
0.36 pg/ml (50 μl);0.85 pg/ml (10 μl)
| pg/ml | O.D. | Average | Corrected | |
|---|---|---|---|---|
| 0.00 | 0.0117 | 0.0121 | 0.0119 | |
| 1.37 | 0.0250 | 0.0282 | 0.0266 | 0.0147 |
| 4.12 | 0.0462 | 0.0489 | 0.0476 | 0.0357 |
| 12.35 | 0.1248 | 0.1240 | 0.1244 | 0.1125 |
| 37.04 | 0.3399 | 0.3393 | 0.3396 | 0.3277 |
| 111.11 | 0.9201 | 0.8954 | 0.9078 | 0.8959 |
| 333.33 | 2.0160 | 1.9910 | 2.0035 | 1.9916 |
| 1000.00 | 3.6940 | 3.6730 | 3.6835 | 3.6716 |
精度
| Intra-Assay Precision | Inter-Assay Precision | |||||
| Sample Number | S1 | S2 | S3 | S1 | S2 | S3 |
| 22 | 22 | 22 | 6 | 6 | 6 | |
| Average (pg/ml) | 17.2 | 98.2 | 273.3 | 18.9 | 91.8 | 240.1 |
| Standard Deviation | 0.5 | 3 | 6.8 | 0.8 | 2.7 | 5.2 |
| Coefficient of Variation (%) | 2.8 | 3.2 | 2.5 | 4.2 | 3 | 2.1 |
Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision. Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.
スパイク回収
The spike recovery was evaluated by spiking 3 levels of human IFN gamma into health human serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 89% to 113% with an overall mean recovery of 105%
サンプル値
| Sample Matrix | Sample Evaluated | Range (pg/ml) | Detectable (%) | Mean of Detectable (pg/ml) |
|---|---|---|---|---|
| Serum | 30 | n.d.-446.28 | 92 | 93.56 |
Serum/Plasma – Thirty samples from apparently healthy volunteers were evaluated for the presence of IFN-gamma in this assay. No medical histories were available for the donors.
n.d. = non-detectable. Samples measured below the sensitivity are considered to be non-detectable.
実験タイプ
種属反応性
検出方法
所要時間
標準曲線梯度
インキュベーション回数
2
Detectable Sample
サンプル添加量
製品の特徴
保存条件
2-8 ℃で保存
文献におけるアプリケーション
| ELISA | 下記の<%= count %>篇の文献を見る |
文献におけるアプリケーション
| Human | 下記の<%= count %>篇の文献を見る |
ターゲット
UNIPROT #
別名
IFG
IFI
IFN gamma
IFN, immune
IFN-gamma
IFNG
IFNG_HUMAN
Immune interferon
Interferon gamma
機能
文献・引用論文
-
A ceramic microbridge microfluidic chip to study osteogenic differentiation of mesenchymal stem cells in bioactive ceramic immune microenvironment
ジャーナル: Bioactive Materials
DOI: 10.1016/j.bioactmat.2024.11.005
IF: 18
アプリケーション: ELISA
交差反応性: Human
掲載日: 2024 Dec
同一ターゲット・同一パスウェイ製品