Mouse IL-17A enzyme-linked immunoassay kit
Catalog# EM0008
Mouse IL-17A enzyme-linked immunoassay kit
-
ELISA
-
Mouse
-
4.12~3000 pg/ml
-
unconjugated
Safety datasheet
Select your chosen country/region
- MSDS_HUABIO.pdf
- MSDS_HUABIO.pdf
- MSDS_EM0008_Europe.pdf
- No MSDS Found
製品概要
製品名
Mouse IL-17A enzyme-linked immunoassay kit
製品タイプ
Elisa Kit
検出感度
0.39 pg/ml (10 μl)
| pg/ml | O.D. | Average | Corrected | |
|---|---|---|---|---|
| 0.00 | 0.0084 | 0.0077 | 0.0081 | |
| 4.12 | 0.0150 | 0.0143 | 0.0147 | 0.0066 |
| 12.35 | 0.0299 | 0.0300 | 0.0300 | 0.0219 |
| 37.04 | 0.0777 | 0.0786 | 0.0782 | 0.0701 |
| 111.11 | 0.2320 | 0.2267 | 0.2294 | 0.2213 |
| 333.33 | 0.6311 | 0.6392 | 0.6352 | 0.6271 |
| 1000.00 | 1.6010 | 1.6680 | 1.6345 | 1.6265 |
| 3000.00 | 3.3530 | 3.5300 | 3.4415 | 3.4335 |
精度
| Intra-Assay Precision | Inter-Assay Precision | |||||
| Sample Number | S1 | S2 | S3 | S1 | S2 | S3 |
| 22 | 22 | 22 | 6 | 6 | 6 | |
| Average (pg/ml) | 40.2 | 254.7 | 867.4 | 43.0 | 235.5 | 947.6 |
| Standard Deviation | 1.9 | 8.7 | 39.6 | 1.7 | 7.6 | 44.7 |
| Coefficient of Variation (%) | 4.8 | 3.4 | 4.6 | 3.9 | 3.2 | 4.7 |
Intra-assay Precision (Precision within an assay) Three samples of known concentration were tested Twenty-two times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays) Three samples of known concentration were tested six times on one plate to assess intra-assay precision.
スパイク回収
The spike recovery was evaluated by spiking 3 levels of mouse IL-17A into health mouse serum sample. The un-spiked serum was used as blank in this experiment.
The recovery ranged from 82% to 115% with an overall mean recovery of 102%.
サンプル値
| Sample Matrix | Sample Evaluated | Range (pg/ml) | Detectable (%) | Mean of Detectable (pg/ml) |
|---|---|---|---|---|
| Serum | 30 | 1.95-11.76 | 100 | 5.45 |
Serum/Plasma – Thirty samples from apparently healthy mice were evaluated for the presence of IL-17A in this assay. No medical histories were available for the donors.
n.d. = non-detectable. Samples measured below the sensitivity are considered to be non-detectable.
実験タイプ
種属反応性
検出方法
所要時間
標準曲線梯度
インキュベーション回数
2
Detectable Sample
サンプル添加量
製品の特徴
保存条件
2-8 ℃で保存
文献におけるアプリケーション
| ELISA | 下記の<%= count %>篇の文献を見る |
文献におけるアプリケーション
| Mouse | 下記の<%= count %>篇の文献を見る |
ターゲット
UNIPROT #
別名
CTLA 8
CTLA-8
CTLA8
Cytotoxic T lymphocyte associated antigen 8
Cytotoxic T lymphocyte associated protein 8
Cytotoxic T lymphocyte associated serine esterase 8
Cytotoxic T-lymphocyte-associated antigen 8
IL 17A
IL-17
IL-17A
展開CTLA 8
CTLA-8
CTLA8
Cytotoxic T lymphocyte associated antigen 8
Cytotoxic T lymphocyte associated protein 8
Cytotoxic T lymphocyte associated serine esterase 8
Cytotoxic T-lymphocyte-associated antigen 8
IL 17A
IL-17
IL-17A
IL17
IL17_HUMAN
Il17a
Interleukin 17 (cytotoxic T lymphocyte associated serine esterase 8)
Interleukin 17A
Interleukin-17A
Interleukin17
Interleukin17A
OTTHUMP00000016597
OTTMUSP00000046003
折りたたむ機能
文献・引用論文
-
Jianpi Fuzheng Xiaoji Formula Ameliorates Gastric Precancerous Lesions via Suppression of Neutrophil Extracellular Trap Formation
ジャーナル: Journal Of Ethnopharmacology
DOI: 10.1016/j.jep.2026.121459
IF: 5.4
アプリケーション: ELISA
交差反応性: Mouse
掲載日: 2026 Mar
同一ターゲット・同一パスウェイ製品